Integrity-Tested Fire-Rated Duct Assembly

Integrity-Tested Fire-Rated Duct Assembly


Specifications
Details

Integrity-Tested Fire-Rated Duct Assembly by EKG M&E Sdn Bhd

In the rigorous safety environment of Kuala Lumpur and Selangor, a "fire-rated" label is not enough. An Integrity-Tested Fire-Rated Duct Assembly refers to a complete system—comprising the duct, hangers, seals, and penetrations—that has been physically tested as a single unit to withstand a fire. EKG M&E Sdn Bhd specializes in the installation of these pre-engineered assemblies, ensuring that your building's air distribution system maintains its 2-hour fire resistance under the most extreme thermal stress.


The Engineering of a Certified Assembly

Integrity testing (under standards like BS 476 Part 24 or ISO 6944) evaluates how the entire assembly interacts during a fire. It is not enough for the metal to survive if the hangers fail or the joints leak.

1. Stability, Integrity, and Insulation (FRL 120/120/120)

Our assemblies are certified to maintain performance for 120 minutes:

  • Stability (Failure of Support): The assembly must not collapse. We utilize reinforced, fire-rated hanger systems with oversized threaded rods and steel C-channels that account for the thermal expansion of the metal.

  • Integrity (Passage of Flame): The assembly must remain smoke-tight and flame-tight. Every longitudinal and transverse joint is sealed with certified intumescent gaskets that prevent "burn-through."

  • Insulation (Temperature Rise): The assembly prevents radiant heat from transferring to the "cold side." This ensures that materials outside the fire zone (like data cables) do not ignite spontaneously.

2. Penetration & Expansion Management

  • Expansion Bolsters: Stainless steel undergoes significant expansion at high temperatures. Our assemblies include engineered expansion joints that allow the duct to grow without buckling or destroying the fire-rated wall it passes through.

  • Certified Fire-Stopping: At every wall or floor penetration, we utilize an integrated fire-stop system that expands to create a permanent, non-combustible plug, maintaining the building's fire compartmentation.


Critical Operational & Energy Benefits

As a BOMBA-Compliant M&E Specialist, EKG ensures that integrity-tested assemblies support long-term operational efficiency:

  • TNB Energy Efficiency (The Airtight Standard):

    Because these assemblies are tested for integrity, they are inherently airtight (Class C or D). This minimizes static pressure loss during daily use. By eliminating air leakage, your Variable Frequency Drive (VFD) can maintain required airflows at lower frequencies (Hz), directly resulting in a lower monthly TNB electricity bill.

  • EECA 2024 & Building Sustainability:

    Under the Energy Efficiency and Conservation Act (EECA) 2024, efficient mechanical transport is mandatory. Our precision-sealed assemblies prevent the leakage of conditioned air into unconditioned ceiling voids, protecting your Building Energy Index (BEI).

  • Reduced Life-Cycle Cost:

    By installing a pre-engineered assembly rather than a "field-fabricated" solution, you ensure consistent quality. These systems are designed to last 30 to 50+ years with minimal maintenance, providing the lowest life-cycle cost for KL property owners.


Performance Requirement Matrix

Feature Field-Fabricated Ducting EKG Integrity-Tested Assembly
Certification Component-based Complete System (Product Certificate)
Airtightness Class A / B Class C / D (High Performance)
Expansion Control Often Overlooked Integrated Expansion Bolsters
BOMBA Acceptance Subject to Inspection Pre-Approved (Standardized)
Hanger System Standard Commercial Reinforced Fire-Rated Supports

Why Choose EKG M&E Sdn Bhd?

  • Total 3D BIM Coordination: We utilize advanced 3D modeling to route these assemblies through crowded ceiling spaces, ensuring zero "clashes" with fire sprinklers or structural beams while maintaining mandatory fire separation.

  • Turnkey BOMBA Submission: We provide all necessary test reports and material data sheets required for Fire Certificate (FC) applications and annual renewals.

  • Total Performance Commissioning: Post-installation, we perform mandatory Duct Leakage Tests (DW/143) and Smoke Tests to certify the assembly is performing as designed.

Is your facility's fire safety based on guesswork or a tested assembly? Contact EKG M&E Sdn Bhd today for a professional integrity-tested ducting audit and technical proposal.


View more about Integrity-Tested Fire-Rated Duct Assembly on main site